Best Thermocouple Type

Fluke 52-2 Dual Input Digital Thermometer, 3 AA Battery, -418 to 2501 Degree F Range, 60 Hz Noise Rejection

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in Celsius, Fahrenheit, or Kelvin via a Type K, Type J, Type T, or Type E thermocouple probe.
  • Includes a Type K bead thermocouple probe with a 40" cable that measures from -40 to +260 degrees C (-40 to +500 degrees F).
  • Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
  • Conforms to NIST standards for compliance with regulations.
Check Stock

Digital pyrometer F,C pottery ceramic glass kiln Sensor Thermometer Thermocouple

  • Digital Pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F).
  • Ceramic thermocouple Temperature range: -50°C to 1300°C ( -58°F to 2372°F).
  • Included Pyrometer and 2 type K thermocouple ( One 3" K type thermocouple(-50 to 400°C) and one Kiln K type (-50 to 1300°C)).
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Shipping to USA is 3-6 business days. For more information please go to our website Thermomart.
Check Stock

ennoLogic Volt mA Thermocouple Loop Process Calibrator eC370T - 0-20V and 4-20mA Simulator – Portable Millivolt mA and Temperature Signal Generator and Meter for Transmitters Current Loops PLC

  • VERSATILE AND ACCURATE VOLT MA THERMOCOUPLE CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, thermocouples, PLC, temperature control and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV, V, Celsius and Fahrenheit ranges)..
  • NUMERIC KEYPAD for ease and flexibility in setting output signals configuring options. HOTKEY programming for each numeric key (long-press immediately outputs user-configured voltage, current or temperature signal). RAMP AND LADDER OUTPUT FUNCTIONS can be custom configured. BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops..
  • MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution, 0.06% accuracy) and 0-20V (1mV resolution, 0.08% accuracy). MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.08% accuracy. MEASURE THERMOCOUPLE TEMPERATURES within a range of -250°C to +1800°C and resolution of ±0.7°C to ±2°C (range and resolution depends on thermocouple type, supported are type K, J, E, T, N, S, R, and B.).
Check Stock

MENSI Outdoor Propane Gas Patio Heater Replacement Parts Safety Thermocouple Sensor

  • Propane gas patio heater dump switch type thermocouple end nuts for valve M8*1.
  • Two terminals connect dump switch on the patio heaters.
  • Thermocouple tip thread M6x0.75 universal type (Can adjust height easily by nuts).
  • Easy install - Head for heating around burner and thread nuts for valve other two terminals for dump switch.
  • The thermocouple can connect a thermostat as well. Keep the head to be heated always or it may stopped gas.
Check Stock

K Type Thermocouple Temperature Thermocouple Sensor Temperature Detector Temperature Gauge with M4 Thread for 3D Printer Temperature Sensor

  • Type K (chromel–alumel) is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.[10] It is inexpensive, and a wide variety of probes are available in its −200 °C to +1350 °C (−330 °F to +2460 °F) range. Type K was specified at a time when metallurgy was less advanced than it is today, and consequently characteristics may vary considerably between samples. One of the constituent metals, nickel, is magnetic.
  • a characteristic of thermocouples made with magnetic.
  • They operate very well in oxidizing atmospheres. If, however, a mostly reducing atmosphere (such as hydrogen with a small amount of oxygen) comes into contact with the wires, the chromium in the chromel alloy oxidizes. This reduces the emf output, and the thermocouple reads low. This phenomenon is known as green rot, due to the color of the affected alloy. Although not always distinctively green, the chromel wire will develop a mottled silvery skin and become magnetic. An easy way to check for t.
  • Hydrogen in the atmosphere is the usual cause of green rot. At high temperatures, it can diffuse through solid metals or an intact metal thermowell. Even a sheath of magnesium oxide insulating the thermocouple will not keep the hydrogen out..
Check Stock

DANOPLUS High Accuracy Digital K-Type Thermocouple Thermometer (-50~1300°C) with Dual Channels 4 Probes (Wired & Stainless Steel) Handheld High Temperature Kelvin Scale Meter Tester

  • Designed to work with 2 external K-Type thermocouples for high-temperature measurement ranging from -50 ~ 1300°C (-58 ~ 2372°F)..
  • Comes with built-in microcontroller software & dual thermocouple input terminals that enable simultaneous measurement of two samples.
  • Precision: Reading Accuracy (±0.1°C ±0.4) & fast response with K-Type Thermocouple Probes.
  • Comes with a removable silicon rubber holster to protect your device from an accidental drop.
  • Practical - any standard K-Type thermocouple connectors can be used to replaced the included thermocouples when it needed a replacement.
Check Stock

2 Pcs Digital 2 Channels K Type Thermometer with 8 Thermocouples (Wire and Stainless Steel) -50~1300°c (-58~2372°f) Dual Measurement Meter Sensor Handheld HVAC Thermometer High Temperature Pyrometer

  • High Accuracy: reading accuracy (±0.1°C ±0.4), fast response using K type thermocouple probe, this digital temperature gauge will bring you a lot of convenience.
  • You will get 2 pcs of K type thermometers, 4 pcs of wire thermocouples and stainless steel thermocouples.
  • Multiple Temperature Display: in addition to the max/ min/ average, data hold, and auto power off functions, this hand held temperature reader is specially designed with a "T1-T2" calculation function, making it easy for the user to find the difference between two samples.
  • ​Portable and Practical: powered by battery, this thermometer with probe is portable and practical, operate it with 6 simple buttons with clear instructions, suitable for beginners and skilled users.
  • Plus, the removable silicone rubber cover protects your device from accidental drops.
  • It is factory calibrated and factory reset, and any standard K type thermocouple connector can be applied to replace the included thermocouple when needed.
  • Wide Measurement Temperature Range: mainframe range of digital k type thermometer is about -50°C ~ 1300°C (-58°F ~ 2372°F).
Check Stock

Cooper Atkins 35132 Aquatuff with Wrap&Stow Duraneed

  • Waterproof Thermocouple Thermometer - Precise digital thermocouple thermometer, delivers a true +/- 0.9 degrees Fahrenheit accuracy and probes can be replaced in the field without the need for recalibration.
  • Heavy Duty Probe Cable - Patented thermocouple thermometer probe cable that neatly wraps and stows around the instrument. Uses any K Type probe.
  • DuraNeedle Probes - Best used for dense meats. Also works well with soft foods and liquids. Probe is calibrated with instrument for Total System Accuracy.
  • Waterproof Digital Thermocouple - Large easy to read digital LCD display, auto shutoff after 10 minutes of non-use. IPX7 waterproof rated.
  • Cooper-Atkins Corporation - Headquartered in Middlefield, CT, Cooper-Atkins has been a leading manufacturer of quality time, temperature, and humidity instruments serving the Foodservice, HVAC and Healthcare markets since 1885.
Check Stock

Fluke BC-7240 Battery Charger/Eliminator, For 75X Documenting Process Calibrator

  • Dual infrared and thermocouple thermometer for noncontact or contact temperature measurement in HVAC/R systems and manufacturing, electrical, and industrial environments.
  • Measures temperature from 40 to Plus-550 degrees C ( 40 to Plus-1022 degrees F) with an accuracy of plus or 1 degree C (plus or 2 degrees F) for the infrared sensor and an accuracy of plus or 2 degrees C (plus or 4 degrees F) or 1 percent of the reading, whichever is greater, for type K thermocouple input.
  • 12:1 infrared distance to spot ratio with laser sighting for pinpointing the measurement area.
  • Included type K thermocouple pipe probe wrapped in flexible hook and loop fastener with a 20 inch cable takes contact measurements from 0 to 100 degrees C (32 to 212 degrees F).
  • CE mark indicates compliance with applicable EU directives.
Check Stock