VEVOR Air Compressor Electric Motor, 5 HP SPL 3450 RPM, 208-230 Volt 3.1 KW Single Phase, 56 Frame 5/8" Keyed Shaft 60 Hz, Commercial-Duty CCW Rotation, 1.88" Shaft Length NEMA for Air Compressors
Single Phase Induction Motor: This compact powerful electric motor runs at 5 HP SPL 3450 RPM max speed. Frame type: 56. Input power: 3.1 kW. Full Load Amp: 15 - 16 A. Voltage: 208-230 V 60 Hz. Rotation: Non-reversible CCW. Shaft length: 1.88 in / 4.8 cm. Shaft diameter: 5/8 in / 1.59 cm keyed. Phase: Single phase. Service factor: 1.15..
Steel Housing: The motor shell is made of steel. The robust and reliable body can guard the internal circuit well against overheating. The attached steel bracket also offers excellent stability. Two capacitors and high-quality ball bearings ensure long service life..
Overload Thermal Protector: The heavy-duty electric motor adopts a manual reset knob against high-temperature overload. Reduced starting amperage design ensures the reduced voltage starting at a rated load. Insulation class-F, ENC-IP23, Ambient temperature-104℉ / 40℃, Duty-CONT, Pole-2..
Heat Dissipation Holes: The air compressor motor has multiple heat dissipation strips for heat dissipation. It can also guard chips and objects against dropping in the motor and causing accidents..
ATO 110v vfd, single phase 110v/120v input, single phase or three phase 220v output, achieve to run 220v AC motor on single phase 110v/120v power supply.
【Voltage& Frequency】Input voltage: 1 phase 120V AC ±15%, Input frequency: 50Hz/60Hz,Output voltage: 1 phase or 3 phase 220V AC ±15%, Output frequency: 0.00~400.00Hz.
【APPLICATION】ATO 7.5 hp 5.5kW variable frequency drive Can be widely applied to drive the AC motor, such as fans, pumps, power tools, etc.
【TIPS】 To protect the variable frequency drive and Motor, you need an upstream protection, add a line-choke upstream the VFD, this will reduce the current transients seen by the input of the VFD.
【CUSTOMER FIRST】If you have no experience in driving a VFD, be sure to refer to the instructions before operating a VFD.If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h.
The base of the protector adopts a rail type with two screw holes, which can be directly installed separately or mounted on the HT35 rail..
Use 5 indicators to indicate: normal, phase loss (voltage three-phase unbalance), reverse phase, overvoltage and undervoltage..
Phase loss protection means that when the protected line is in the running state or non-operating state, any phase failure occurs, and the delay is 2S..
Overvoltage protection means that the voltage of the protected line is higher than the set value, and the delay is 3~8S, and the recovery is 6~20VAC..
Reverse phase protection, a protection measure to prevent L1, L2, L3 three-phase AC phase sequence from being connected incorrectly, delay 2S action..